Back to Case
Studies
Bench-Scale Treatability Study Treatment of FREON and
Chlorinated Hydrocarbons Using VeruTEK's S-ISCO™ Coelution
Technology™
Download PDF Version: Treatment of FREON andChlorinated Hydrocarbons
Using VeruTEK's S-ISCO™ CoelutionTechnology™
Groundwater samples were collected from a former industrial
manufacturing facility with moderate FREON-113 and chlorinated
hydrocarbon contamination. These samples were characterized to
determine initial FREON-113 and other volatile compound
contamination levels prior to using in three laboratory tests:
- Test 1: No treatment (control)
- Test 2: Alkaline persulfate
- Test 3: Fe-EDTA Catalyzed Persulfate
Each test contained the same amount of groundwater. Each test
also contained approximately the same amount of contaminants
initially; the table and graph below demonstrate the effectiveness
of S-ISCO™ in destroying FREON-113 and chlorinated hydrocarbon
contamination after 5 days:


Treatment with S-ISCO™ using Alkaline Activated Persulfate
technology led to the destruction of 100% of the
FREON-113 and chlorinated hydrocarbon contamination in just 5
days.